The current version is 1.7.0.7
Once updated and connected, you can set the switcher to either a DHCP (default) or Static IP address. With static, you can then directly connect your 1200 to a PC for operation without a router.
If there are any issues initially connecting the unit to the router, I recommend following the below steps to troubleshoot any local network issues:
Connect PC and 1200 to same router
Log into router
Set LAN gateway IP to 192.168.1.1
(Via LAN setup, check router's user manual for steps)
Restart switcher
Look at attached devices connected via Ethernet
MAC Address should be same/similar to
1E:ED:19:27:1A:B3
Change to static IP of device to 192.168.1.101
(Via DHCP/Address reservation, check router's user manual for steps)
Restart router
Restart computer
Once both have booted,
Restart switcher
Load SE-Controller
Click setup
Check that both panel and processor show a 1.1.1.7 version
If panel is newer than processor, run software update
Once updating pop up disappears close SE-Controller
Restart switcher
Load SE-Controller
Click setup again
Panel and processor version should match now